Plug Load Control
Plug load control comes in two basic forms. Energy savings are achieved when the device is either transitioned to a low-power state, or it is de-energized to eliminate the power draw. Both can be executed either manually or automatically. A low-power state is between a de-energized state and a ready-to-use state. This includes standby, sleep, and hibernate modes as well as any “off” state that has a parasitic power draw. A de-energized state is when electricity is not being provided to the device. This is analogous to physically unplugging a device’s power cord from a standard electrical outlet.
The most prevalent plug load contral strategies include:
Manual Control: Most plug-loads can be manually powered down with built-in power buttons, shutdown procedures, or a control device that energizes and de-energizes electrical outlets based only on manual input. The effectiveness of manual control depends entirely on user behavior and should be implemented only if no other methods apply.
Automatic Low-Power State: The first, and in some cases most effective, control method is a built-in, automatic low-power state functionality such as standby or sleep. Some manufacturers include this functionality to reduce energy consumption of idle devices. Internal processes monitor idle time, and when the device has been in an idle state for a given period, it will power down to a low-power state.
Schedule Timer Control Device: Certain plug-loads have predictable load profiles. These devices are used during the same times each day or at regular intervals. A scheduling-control device can effectively manage a predictable plug-load. It applies user-programmed schedules to de-energize the plug-load to match its use pattern and energize the plug-load so that it is ready for use at the time when it is required.
Load-Sensing Control Device: Plug loads may have a primary-secondary relationship. A primary device, such as a computer, operates independently of other (slave) devices. A secondary device, such as a monitor or other peripheral, depends on the operation of other (master) devices. A load-sensing control device should be implemented for such a relationship. It automatically energizes and de-energizes secondary devices based on the “sensed” power load of the primary device(s). Whenever the primary device goes into a power state below a given threshold, the load-sensing control can power down the secondary devices. The sensed (primary) load is typically an electrical outlet or an auxiliary port (e.g., universal serial bus (USB) in the case of a computer).
Occupancy-Control Device: Occupancy control can save a great deal of energy as it energizes plug-loads only when users are present and de-energizes them when the space is vacant. This approach pinpoints the main source of wasted energy during non-business hours and reduces wasted energy during business hours. However, the largest drawback is that occupancy controlled devices may energize and de-energize outlets at inappropriate times.
Manual-On, Vacancy-Off Control Device: A manual-on, vacancy-off control device is a slight modification of the occupancy-control device. It energizes a plug-load when it receives manual input from a user and de-energizes the plug-load automatically based on lack of occupancy. This control should be implemented for plug-loads that are needed only when users are present (e.g., task lights, monitors, and laptops).
Procure Products
in the Green Procurement Compilation55 Results : Plug Load Control
-
Transformation to Net Zero Energy Buildings - GSA Sustainable Facilities Tool
...facilitate conversion to renewable energy? Load reduction. Develop policies and active...installing (or programming) automatic controls. Examples include: Vacancy or occupancyhttps://sftool.gov › plan › 421 › transformation-net-energy-buildings -
N232
...treated/remediated groundwater  Bioswales control and filter run-off  Fast-growing...architectural, mechanical, plumbing, power, controls and interior design  Monitor real-timehttps://sftool.gov › Content › attachments › Iswg › iswg-case-studies › NASA Ames Sustainability Base_SDianati Nov 2012.pdf -
PowerPoint Presentation
...(EEx) - Cybersecurity Technologies and Control Systems CEU - # 9 / FBPTA - #4 Technical...- Expert: FEMP Facility Related Control Systems Security - Expert: FEMP THURSDAYhttps://sftool.gov › Content › attachments › Iswg › iswg-tools › EEx -BBS Overview _ISWG_July 2018 (Baker).pdf -
Sustainable Response to COVID-19 - GSA Sustainable Facilities Tool
Guideline 11-2018, Field Testing of HVAC Control Components Ventilation, Filtration...mechanical systems and engineering controls avoid generic “one-size-fits-allâ€https://sftool.gov › learn › about › 625 › sustainable-response-covid-19 -
MaterialDetails - GSA Sustainable Facilities Tool
Manual Control Description Most plug-loads can be manually powered down with...buttons, shutdown procedures, or a control device that energizes and de-energizeshttps://sftool.gov › material › 2164 › manual-control -
Site Map - GSA Sustainable Facilities Tool
Quality (IEQ) Materials & Resources Plug Loads Sustainable Response to COVID-19...Air Conditioning (HVAC) Building Plug Loads Buildings' Energy Use Buildings'https://sftool.gov › home › sitemap -
Building Certification Standards Crosswalk - GSA Sustainable Facilities Tool
Environment: Daylighting and Lighting Controls GP 4.3. Enhance the Indoor Environment:...Indoor Environment: Moisture and Mold Control GP 4.6. Enhance the Indoor Environment:https://sftool.gov › learn › GRScrosswalk -
Healthy Cleaning - GSA Sustainable Facilities Tool
...workplace and implementing appropriate control measures to protect employee health...conserve energy and decrease GHGs. Plug loads: Unplug cleaning equipment when nothttps://sftool.gov › learn › about › 645 › healthy-cleaning -
Building Operations and Maintenance Services - GSA Sustainable Facilities Tool
Ensure occupant comfort Enable occupant control of ambient conditions in workspaces...workspaces through individual or zone control of ventilation and temperature Ensurehttps://sftool.gov › plan › 268 › building-operations-maintenance-services -
ISWG
...building Plug and process loads not included in modeling Lighting controls not...effectively Legacy data center Plug and Process Loads ENERGY STAR rating droppedhttps://sftool.gov › Content › attachments › Iswg › iswg-case-studies › 13 Judith Heerwagen - EPA Denver Demonstration Project.pdf -
Post Consumer Fiber Paper - GSA Sustainable Facilities Tool
Recycling Basics Share Did You Know? Plug loads can average approximately 30% of...attributed to parasitic loads (power draw of a plug-load that is not performinghttps://sftool.gov › learn › about › 201 › post-consumer-fiber-paper -
Electric Vehicles and Electric Vehicle Supply Equipment - GSA Sustainable Facilities Tool
...vehicles, including battery electric, plug-in hybrid electric, or fuel cell electric...External Space Battery Electric Vehicle Plug-In Hybrids (PHEV) Electric Vehicle Supplyhttps://sftool.gov › learn › about › 666 › electric-vehicles-electric-vehicle-supply-equipment -
Mandates / Standards > Submetering - GSA Sustainable Facilities Tool
...light and lighting controls by floor or by zones, plug loads by floor or by zone...electrical equipment, critical HVAC controls? Is there sub-metering for all water-intensivehttps://sftool.gov › explore › green-building › section › 90 › submetering › relevant-mandates-and-rating-systems -
Sustainability Program Development - GSA Sustainable Facilities Tool
...sustainability efforts. Share Did You Know? Plug loads can average approximately 30% of...attributed to parasitic loads (power draw of a plug-load that is not performinghttps://sftool.gov › learn › about › 481 › sustainability-program-development -
PowerPoint Presentation
...33% Small Office DHW HVAC Lighting Plug Loads 6U.S. DEPARTMENT OF ENERGY OFFICE...33% Small Office DHW HVAC Lighting Plug Loads HWTM 7U.S. DEPARTMENT OF ENERGY OFFICEhttps://sftool.gov › Content › attachments › Iswg › iswg-case-studies › Hot Water Temperature Maintenance Efficiency Opportunities.pdf -
Slide 1
Understand Existing Conditions (4) Reduce Loads (5) Select Appropriate & Efficient...Technology (6) Find Synergies (7) Optimize Controls (8) Incorporate Renewables (9) Realizehttps://sftool.gov › Content › attachments › Iswg › iswg-case-studies › 11 CaraCarmichael Victor Olgyay - RMI Deep Energy Retrofits.pdf -
Upgrades - GSA Sustainable Facilities Tool
https://sftool.gov › plan › upgrades -
Proposed New Recognition: ENERGY STAR Tenant Space
...build/fit-out Charter Tenants Automatic Controls Company, Inc. CodeGreen Solutions...for in building. Includes lighting, plug-load, supplemental HVAC (if applicable)https://sftool.gov › Content › attachments › Iswg › iswg-policies-strategies › 4 - EPA ISWG meeting 2_2020.pdf -
Slide 1
...implemented total cost $2.3M Install Controlled outlets Develop and Apply Unique...Unique schedules for lighting, plug loads, temperature setpoints and fans base onhttps://sftool.gov › Content › attachments › Iswg › iswg-case-studies › LA Courthouse - D Allen GSA - ISWG 180517.pdf -
PowerPoint Presentation
Externality Costs Varied methods Cost of control Willingness-to-pay Estimating...operating energy oriented (reduce plug loads) and others were more operationalhttps://sftool.gov › Content › attachments › Iswg › iswg-case-studies › Sustainable Building Study Using Whole-System and Life-Cycle Thinking - JParisi, Nov. 2012.pdf
Page 1 2 3